If the weight displayed on the console is greater than
the weight actually measured, the calibration number
will increase.
J. Turn the Mode Selector to SET-UP and use the
INC./DEC. switch to change the Spreader Con-
stant. (REMEMBER, IF SPLIT DRIVE IS ACTIVE,
THE BOOMS MUST BE ON.) Turn the booms
OFF and switch the Mode Selector back to
OPERATE, the corrected Indicated Amount will
be displayed. If this number does not match the
actual amount, check the calculation.
If it is not convenient to conduct an actual test, field
experience will allow fine tuning of the spreader constant.
If the vehicle is applying too much, decrease the spreader
constant by the same percentage as the over application.
If too little material is being discharged, increase the
spreader constant by the same percentage as the under
application.
Suggestion: Make a list of spreader constants for
different product/gate setting combinations. This will
allow you to change from one product or gate setting to
another with a minimum of recalibration.
S
ETTING
A
UTO
P
OWER
D
OWN
T
IME
T
he CE console has an "Auto Power Down" feature
which powers the console off after an operator
selectable period (default is 30 min) has elapsed. If
no input is received from the speed sensor or any console
switch during this time the APD feature is activated. The
APD time can be set from 15 to 60 minutes. Selecting a
period less than 15 minutes disables the APD feature.
A. Use the following switch settings to adjust the
Auto Power down time:
1. Power
OFF
2. Mode selector
SET-UP
3. Display selector
% Rate
4. Hold the INC switch
UP while
turning the power on
The display will show the current Auto Power
Down time.
Mid-T
Mid-T
ech
ech
DISPLAY SELECTOR
Speed
Area
Impl. Width
Distance
Test
Speed
PSI/Prime
Total Applied
Application Rate
OFF
SET- UP
DEC.
ON
OPERATE
INC.
Scan
Product Vol.
Fan RPM
BOOMS
1 2 3 4 5 6 7 8 9
% Rate
A-1
A-2
A-3
B