beautypg.com

TeeJet TASC-6100 User Manual

Page 54

background image

5-2

TASC 6100

98-05018

R2

CE & S

TANDARD

V

ERSION

Clean screens.

Contact your MID-TECH
dealer if you see this
message on a TASC 6100
controller.

Refill tank.

Check for ruptures or leaks
at joints, fittings, etc.

Turn product pump ON.

Check for correct operation
of hydraulic valves feeding
the pump motor.

Check for air lock in the
product pump, causing no
output. Purge pump using
the PRIME function.

Check for blockage in
product strainers.

Check “Flow Control”
connections on the back of
the console. Secure if loose.

Check in-line fuse (optional)
near + battery connection.

Check valve control signals.

Err 1
Pump L
(Cont.)

Err 2

Err 3
Pump L

Strainer or nozzle screens
plugged.

Pressure LOW, main

strainer;

Pressure HIGH, nozzle

screens.

Not a diagnostic function in
the TASC 6100 console.

Console is not receiving
pulses from the flow sensor.
Check for actual spraying at
nozzles.

No flow in the product line.

Main supply tank is empty.

Leak in main feed line.

No output from product
pump.

Obstruction in main supply
line.

Main flow control valve not
opening.