Entering the flow sensor calibration number – TeeJet TASC-6100 User Manual

Page 31

background image

2-15

98-05018

R2

CE & StandardVersion

TASC 6100

Setup

& Cal.

2.0 BAR. This is the value to enter into the console as the
pressure sensor cal. #. For example, in the following chart,
for a 8002-SS nozzle, the row for 2.0 BAR and column
for 10 KPH cross at 78.0 Liters per Hectare, the pressure
sensor cal. # for this particular nozzle.

NOTE: You must use the 2.0 BAR / 10 KPH value
regardless of the speed and pressure at which you are
operating.

Use the circled number for the pressure sensor calibra-
tion number.

Entering The Flow Sensor Calibration Number

Use the following procedure to enter the flow sensor
calibration number.

A. Set the console to the following positions;

1. Power

ON

2. Mode Selector

SET- UP

3. Display Selector

Total Applied

4. Master switch

OFF (ON If using

/Booms

Pump L rEFLO)

B. Use the INC./DEC. switch to set the desired flow

sensor calibration number.

NOTE: If the console is in Reflow Mode (Pump L
rEFLOW), the flowsensor cal. # can only be viewed
or changed when all programmed booms are on.

DISPLAY SELECTOR

Speed

Area

Impl. Width

Distance

Test

Speed

PSI/Prime

Total Applied

Application Rate

OFF

SET- UP

DEC.

ON

OPERATE

INC.

Scan

Product Vol.

Fan RPM

BOOMS

1 2 3 4 5 6 7 8 9

% Rate

A-1

A-2

A-3

B

MASTER

ON

OFF

MI

A-4

If using "Pump L rEFLO"

If using "Pump L STnrd"

or "Pump L PSi"

Liters per Hectare

Liquid Capacity

50 cm Spacing

Pressure in

7

8

10

12

Tip No. in bar l/min

km/h

km/h

km/h

km/h

2.0

0.65

111

97.5

78.0

65.0

TP8002-SS 2.5

0.72

123

108

86.4

72.0

3.0

0.79

135

119

94.8

79.0