beautypg.com

TeeJet TASC-6100 User Manual

Page 65

background image

6-5

98-05018

R2

TASC 6100

Emergency

CE & S

TANDARD

V

ERSION

3. Adjust the boom pressure using the INC./

DEC. switch on the control console. INC.
will open the flow control valve and DEC.
will close the valve.

4. Once the desired pressure is attained, turn all

boom sections OFF.

D. Drive to the area to be covered. When the vehicle

reaches the starting point of the desired swath, turn
on the appropriate boom switches and the sprayer
starts to spray. At this point, the operator is
enjoying some monitoring functions of the TASC,
but has no automatic control of the flow control
valve.

E. Monitor Speed. Adjust the ground speed to reach

the target speed desired.

F. The console cannot automatically adjust for

changes in boom widths. If booms are shut off,
pressure must be reset using the INC./DEC.
switch. Areas accumulate normally. Speed reads
correctly.

Mid-T

Mid-T

ech

ech

MID-TECH recommends this procedure as a
temporary, emergency procedure only. The prob-
lem should be resolved as soon as possible to allow
full automatic control of the sprayer to be reestab-
lished.