beautypg.com

TeeJet TASC-6100 User Manual

Page 29

background image

2-13

98-05018

R2

CE & StandardVersion

TASC 6100

Setup

& Cal.

a field calibration/catch test should be performed. (see
page 2-16)

Verify that the correct application program is selected.
(see page 2-1)

Check the Correction Factor, to ensure that it is set
correctly. (see page 2-11)

F

LOWMETER

(for Pump L STnrd applications)

Flowmeters are calibrated for water at the factory and the
suggested calibration numbers are listed below. These num-
bers are meant to be initial cal. #’s since actual flow charac-
teristics may differ, due to plumbing variations or other
factors.

Once the initial calibration number is entered into the
console, per page 2-14, proceed to page 2-16 to fine tune
the flowmeter for maximum accuracy.

Pressure Sensor (U.S. Units)
(for Pump L Psi "US" applications)

The Pressure Sensor calibration number can be found by
determining the "Gallons per Acre" rating for the type of
nozzles being used. Find the chart that represents the
nozzle series you are using and the nozzle spacing of
your boom. Then find the nozzle size needed for the

STANDARD FLOWMETERS

S

IZE

S

UPPLIER

C

AL

. #

S

IZE

S

UPPLIER

C

AL

. #

.75 inch

(Mid-Tech)

396.9

3.00 inch (Mid-Tech)

5.0

1.00 inch

(Mid-Tech)

153.1

1.50 inch (Mid-Tech)

38.8

1.25 inch (Raven) 75.0*

2.00 inch

(Mid-Tech)

23.8

3.00 inch (Raven) 16.4*

MID-TECH RAPID CHECK FLOWMETERS

S

IZE

R

ANGE

C

AL

. #

S

IZE

R

ANGE

C

AL

. #

1.00 inch 0.75 - 5 gpm

3200

1.50 inch 2.5 - 25 gpm

612.4

1.00 inch 2.5 - 16 gpm

800

1.50 inch 2.6 - 53 gpm

361.9

2.00 inch 20.0 - 195 gpm

94.5

* Raven flow meters, use the factory calibration number divided by 10. All other
flowmeters use the manufacturers' supplied information regarding the pulses per
gallon (usually provided on a tag on the flowmeter).