A method similar to the following is recommended.

1. If using Pump L Psi, enter the appropriate "Correc-

tion Factor" for the material that you will be using
for the test (Use factor of 1.00 for Pump L STnrd
applications) (see page 2-11).

2. Enter the desired application rate (see page 2-3).

3. Verify that the boom switches are OFF.

4. Verify that the correct initial flow sensor calibration

number is entered into the console (See pages 2-12
through 2-14). Use the INC./DEC. switch to adjust
as necessary.

5. Reset the Total Applied accumulator to zero (see

page 2-11).

6. Make sure there is enough liquid in the main tank

to perform the test. Weigh the sprayer and load of
water. Position the sprayer in the test area.

7. Start the main carrier pump. Set the Display

Selector switch to Test Speed and the Rate Switch
to “Standard Rate”. Turn ON the Master switch
and the Boom switches. The sprayer starts to spray.
Allow the sprayer to run until the desired amount
of liquid is discharged. Turn OFF the booms

8. Weigh the sprayer again and calculate the amount

of water discharged.

9. View the total amount of dispensed liquid as

measured by the console (Total Applied/OPER-
ATE
). If the total shown on the console agrees
with the total amount actually discharged, no
further action is necessary. The pressure sensor, or
flowmeter, is now calibrated.

10. If the indicated volume pumped does not agree

with the actual volume pumped, calculate a new
calibration # as follows: