CONTROL CONSOLE USER MANUAL
Six buttons are available for simplifying channel selection:
+
[Clr] - clears all channel selections.
+
[All] - selects all patched channels.
+
[Inv] - (Invert) deselects currently selected channels and selects all other patched channels.
+
[Act] - selects all channels with
active
* luminaires.
+
[Mar] - selects all
marked
* channels.
+
[Z] - selects all channels in a
zero
* state.
Four status mimic buttons are available. These buttons highlight in purple as an indicator rather than as a selection
tool:
+
[Online Status] - indicates all online luminaires.
+
[Active Status] - indicates all luminaires that are
active
*.
+
[Marked Status] - indicates all luminaires that are
marked
*.
+
[Z Status] - indicates all luminaires that are in a
zero
* state.
Four luminaire utility buttons are also available:
+
[Arm] - must pressed first (it will latch on) before pressing [Douse] or [Home/Reset] to complete those commands.
(This prevents accidental dousing or reset actions.)
+
[Start] - starts lamp for all selected arc luminaires with remote start capability.
+
[Douse] - douses lamp for all selected arc luminaires with remote start capability. Press [Arm] then press [Douse]
to send the douse command.
+
[Home/Reset] - dual action button.
[Home] sets parameters to defaults. Press [Arm] then press [Home/Reset] once to send the home command.
[Reset] recalibrates luminaires. Press a [Arm] then press [Home/Reset] twice to send the reset command.
Also refer to
"Home / Reset (Recalibration)"
* Active - luminaires with intensity greater than zero (1-100%).
Marked - luminaires with an intensity state of "marked."
Zero - luminaires with an intensity state of zero ("hard zero", 0% level).
(For a more in-depth explanation, refer to