Setpoint ramp

Setpoint direction

Parameter name

Display

Function

Parameter values

Unit

Factory setting

Customer

setting

If "turn" is selected, you cannot set 33°
Parameter does not appear if 1.YFCT=turn has been selected
Turning points only appear wih selection 10.SFCT = FrEE
Alternatively "no" if initialization has not yet been carried out

NC contact means:
NO contact means:
Normal means:

High level without fault

Inverted means:

Low level without fault

1)
2)
3)
4)

5)

6)

Setpoint turning point at 0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

no / ##.#

Strt

0 MA

4 MA

riSE

FALL

0.0 to 100.0

0.0 to 100.0

AUto

0 to 400

AUto

0.1 to 10.0

Lin

1 : 25

1 : 50

FrEE

0.0 to 100.0

0.0 to 100.0

0.0 to 100.0

MPoS

FLow

no

uP:

:dW

uP:dW

no

Strt

oCAY

Response threshold of alarm

oFF

5 | 10 | 15 | 20

25 | 30 | 35

40 | 50 | 60 | 70 | 90 | 110 | 130

(short lever 33°)

(short lever 90°)

(long lever 90°)

90°

33°

3.YWAY 2)

1)

4.INIT

6.SDIR

7.SPRA

8.SPRE

9.TS

10.SFCT

11.SL0

12.SL1

13.SL2

14.SL3

15.SL4

16.SL5

17.SL6

18.SL7

19.SL8

20.SL9

21.SL10
22.DEBA

23.YA

24.YE

26.YCLS

5.SCUR

3)

5)

5)

6)

6)

25.YNRM

2.YAGL

1.YFCT

(example)

0 to 20 mA

4 to 20 mA

4)

rising

falling

on

uP

doW

StoP

-on

-uP

-doW

-StP

on

bLc1

bLc2

uP

doW

StoP

-on

-uP

-doW

-StP

normal

inverted

inverted

normal

mm

0.0

28.5

50.0

62.6

71.5

78.5

84.1

88.9

93.1

96.7

100.0

oCAY

AUto

s

%

%

10.0

90.0

oFF

oFF

oFF

riSE

no

MPoS

100.0

0.0

AUto

Lin

0

%

%

%

%

s

%

%

mA

100.0

0.0

riSE

4

%

AUto

oFF

Degrees

33°

WAY

no

NC

contact

NC

contact

No

contact

No

contact

Function of BI 1

Function of BI 2

Function of alarm output

action with opened switch or Low level
action with closed switch or High level

Initialization

Current range of setpoint

Setpoint for start of split range

Setpoint for end of split range

Dead zone of controller

Start of manipulated variable limiting

End of manipulated variable limiting

Standardization of

manipulated variable

Tight closing with manipulated variable

Without

Top only

Bottom only

Top and bottom

Leverage ratio (stroke range)

must match set leverage ratio on the actuator

Driver pin must be set to the value of the actuator

travel or, if this value is not scaled, to the next

larger scale value.

Rated angle of rotation of feedback

Type of actuator

turn (part-turn actuator)

WAY (linear actuator)

LWAY (linear actuator

without sine correction)

Set transmission ratio selector (7) appropriately

(see view of device)

Setpoint function

Linear

Equal-percentage 1 : 25

Equal-percentage 1 : 50

Freely adjustable

To mech. travel

To flow

Rising

Falling

1)
2)
3)