Juniper Systems JS600 User Manual
Page 34

Page 3-18 Operating System
▲
▲
▲
▲
▲
Mode 5: Set
The Set Mode has two submodes: Mode 5-1 Set Autolog (SET AUTOLOG), and Mode 5-2 Set
Communication Protocol (SET PROTOCOL).
Mode 5-1 Set Autolog
The Set Autolog submode is used to set the scan interval, units of time, and start time for
automatic data logging. Autolog is used to automatically turn the FieldBook on at a preset
time and start a Polycode program. The program can alert you (by beeping) that it is time
to enter data, or readings can be automatically taken from sensors with RS-232C output.
Instructions for using Mode 5-1 follow.
Keyboard Entry
Next Message Shown
Action
MODE?
Enter a 5 for SET Mode.
5
SET 1,2
Enter a 1 for submode AUTOLOG.
1
LOG N/S/M/H
Enter the units of time to be used for both the
L 1 !N
autologging interval and start time as follows:
N = autolog not in use (default)
S = seconds
M = minutes
H = hours
Units of Time
INTERVAL
Enter the scan interval between executions of
L 1!0
autolog, in the logging units selected. The
interval must be an integer less than sixty if
logging units are minutes or seconds, and less
than 24 if logging units are hours.
Scan Interval
START TIME
Enter the hour, minute, or second you
L 1!
want autologging to start (based on the
internal clock).
Start Time
Autolog is now set. Press ESC to exit.
Guide to Setting Autolog
❏ Before autolog can be enabled, an autolog program must be written and stored in a
program file named AUTOLOG. Otherwise, the following message is displayed when the
FieldBook is turned off and autolog is returned to the default setting (off):
NO AUTOLOG PGM
AUTOLOG RESET