6 16-bit timer/counter 2 (tc2), 1 configuration, 2 control – Toshiba TMP87CP24AF User Manual
Page 74: Toshiba
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

TOSHIBA
TMP87CM24A/P24A
2.6 16-Bit Timer/Counter 2 (TC2)
2.6.1 Configuration
INTTC2
interrupt
Timer/Counter 2 control register
16-bit timer register 2
TREG2H TREG2L
write strobe write strobe
Figure 2-23. Timer/Counter 2 (TC2)
2.6.2 Control
Thetimer/counter
2
is
controlled
by
a
timer/counter
2
control
register
(TC2CR)
and
a
16-bit
timer
register
2 (TREG2). Reset does not affect TREG2.
TREG2
(0016, 001 7
h
)
TC2CR
(0015
h
)
15
14
13
12 11 10
9
8
7 6 5 4 3 2
1
0
_____ ^^________ T,REG2
h
,(0017
h
)___^^_________ _____ ^^________ T’^EG2
l
,(0016
h
)__ ^^_________
7
6
5
4 3 2
1
0
write only
TC2S
TC2CK,
TC2M
(Initial value
:
**00 00*0)
TC2M
Timer/counter 2 operating
0
Timer/Event counter mode
mode select
1
Window mode
000
Internal clock
fc/2^^ or fs/2’=[Hz]
001
Internal clock
fc/2’3 or fs/2=
010
Internal clock
fc/2»
TC2CK
Timer/counter 2
oil
Internal clock
fc/2^
Write
source clock select
100
Internal clock
fc (Note 5)
only
101
Internal clock
fs
110
Reserved
111
External clock (TC2 pin input)
TC2S
Timer/counter 2
0
Stop and counter clear
start control
1
Start
Notel: fc: High-frequency clock [Hz], fs: Low-frequency clock [Hz], *: Don't care
Note 2: When writing to the low-byte of timer register 2 (TREG2i), the comparison is inhibited until
the high-byte (TREG2
h
) is written.
After
writing
to
the
high-byte,
any
match
during
1
machine
cycle
(instruction
execution
cycle) is ignored.
Note 3: Set the mode and source clock when timer/counter stops (TC2S = 0).
Note 4: Values to be loaded to the timer register must satisfy the following condition.
TREG2 > 0(TREG2isfoii>0 when warm-up).
Note 5:
"fc" can be selected as the source clock only in the timer mode during the SLOW mode.
Note 6: TC2CR and TREG2 are write-only registers and must not be used with any of the read-
modify-write instructions.
Figure 2-24. Timer Register 2 and TC2 Control Register
3
-
24-74
2002
-
10-03