Electrical characteristics, Ov ), Toshiba – Toshiba TMP87CP24AF User Manual
Page 125: Tmp87pp24a
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

TOSHIBA
TMP87PP24A
Electrical Characteristics
Absolute Maximum Ratings
(Vss =
ov )
Parameter
Symbol
Pins
Ratings
Unit
Supply Voltage
V
d d
- 0.3 to 6.5
V
Program Voltage
Vpp
TEST/Vpp
-0.3 to 13.0
Input Voltage
V|N
— 0.3 to V
+ 0.3
Output Voltage
V
quti
Except P20 and P3 ports
— 0.3 to V
+ 0.3
V
qut
2
Ports P20, P3
- 0.3 to 5.5
Output Current (Per 1 pin)
buTi
Ports PO, PI, P2, P3, P5, P6, P7, P8, P9, P4
(except P41)
3.2
mA
buT2
P41
30
Output Current (Total)
2 buTi
Ports PO, PI, P2, P3, P5, P6, P7, P8, P9, P4
(except P41)
120
2 buT2
P41
30
Power Dissipation [Торг = 70°C]
PD
350
mW
Soldering Temperature (time)
Tsid
260 (10 s)
°C
Storage Temperature
Tstg
-55 to 125
Operating Temperature
Торг
- lOto70
Note: The absolute maximum ratings are rated values which must not be exceeded during operation, even for an instant. Any
one of the ratings must not be exceeded. If any absolute maximum rating is exceeded, a device may break down or its
performance may be degraded, causing it to catch fire or explode resulting in injury to the user. Thus, when designing
products which include this device, ensure that no absolute maximum rating value will ever be exceeded.
Recommended Operating Conditions
(Vss = OV, Торг = - 10 to 70°C)
Parameter
Symbol
Pins
Conditions
Min
Max
Unit
Supply Voltage
V
dd
fc = 8MHz
NORMAL1,2mode
4.5
5.5
V
IDLE1,2 mode
fc = 4.2MHz
NORMAL1,2mode
2.2
IDLE1,2 mode
fs =
32.768 kHz
SLOW mode
SLEEP mode
STOP mode
2.0
Input High Voltage
ViHi
Except hysteresis input
V
dd
^4.5V
V
dd
^
0.70
V
dd
V|H2
Hysteresis input
V
dd
^
0.75
V|H3
V
dd
<4.5V
V
dd
^
0.90
Input Low Voltage
V|L1
Except hysteresis input
V
dd
^4.5V
0
V
dd
^
0.30
V|L2
Hysteresis input
V
dd
^
0.25
V|L3
V
dd
<4.5V
V
dd
X 0.10
Clock Frequency
fc
XIN, XOUT
V
dd
= 4.5 to 5.5 V
0.4
8.0
MHz
V
dd
= 2.2 to 5.5 V
4.2
fs
XTIN, XTOUT
30.0
34.0
kHz
Note
1:
The
recommended
operating
conditions
for
a
device
are
operating
conditions
under
which
it
can
be
guaranteed
that
the
device
will
operate
as
specified.
If
the
device
is
used
under
operating
conditions
other
than
the
recommended
operating
conditions
(supply
voltage,
operating
temperature
range,
specified
ACIDC
values
etc.),
malfunction
may
occur.
Thus,
when
designing
products
which
include
this
device,
ensure
that
the
recommended
operating
conditions
for the device are always adhered to.
Note 2: Clock frequency fc: Supply voltage range is specified in NORMAL 1/2 mode and IDLE 1/2 mode.
3
-
24-125
2002
-
10-03