Rice Lake MSI-9850 CellScale RF Digital Indicator - Operator Manual User Manual
Page 81

MSI CellScale
®
System • 9850 User Guide Page 81
MEASUREMENT SYSTEMS INTERNATIONAL
Firmware Version 5-XX for 2450 Modems
Output Weight Value and mode @W 1=current weight
2=gross
3=net
4=tare
5=total
6=# of totals
7= total, # of totals
8=reserved
9=last totaled weight
@W1
@W2
@W3
@W4
@W5
@W6
@W7
@W9
**20.002*LB***GROSS*
Length: 20, fixed. Leading zeros suppressed
**205.08*KG***GROSS*
Length: 20, fixed. Leading zeros suppressed
*1188.50*G****NET***
Length: 20, fixed. Leading zeros suppressed
****5000*TNE*TARE**
Length: 20, fixed. Leading zeros suppressed
*432534.85*KG***TOTAL*
Length: 22, fixed. Leading zeros suppressed
12345*T*CNT*
Length: 12, fixed. Leading zeros suppressed
*432534.85*KG***TOTAL,12345*T*CNT*
Length: 34, fixed. Leading zeros suppressed
**200.05*KG***GROSS+*
or NET+ in NetMode
Length: 20, fixed. Leading zeros suppressed
Output a statistics value
@X
@X1
@X2
@X3
@X4
@X5
@X6
@X7
@X8
**13.350
***3.200
**16.650
***2.392
***32.50
4263285.55
*****52.50
*123434
1=Average weight
2=Minimum
3=Maximum
4=Standard Deviation
5=Coeff of Variance
6=Grand Total
7=Grand Average
8=# of Grand Totals
Output a statistics value and
mode
@Y
@Y1
@Y2
@Y3
@Y4
@Y5
@Y6
@Y7
@Y8
**13.350*LB***AVG***
***3.200*LB***MIN***
**16.650*LB***MAX***
***2.392*LB***STDDEV
***32.50*LB***CO-VAR
4263285.55*LB***G-TOTL
*****52.50*LB***G-AVG*
*123434*G-CNT*
1=Average weight
2=Minimum
3=Maximum
4=Standard Deviation
5=Coeff of Variance
6=Grand Total
7=Grand Average
8=# of Grand Totals
Description
Cmd
Command Suffix
Input
examples
Output examples & comments
*= a space or place holder
Go to Index