components: the electrical cables that operate the sensor
and an air tube that ventilates the sensor. Over-tightening
the ties or kinking the cable can damage or restrict the air
tube, causing incorrect pressure depth readings. In
addition, make sure the connector-end of the sensor is not
kinked, does not contain moisture, and includes an
attached dryer tube filled with active blue desiccant.
4. Use the diagonal cutters to cut off the excess portion of the
cable ties.