Gathering the tools and equipment – ADS Environmental Services FlowShark QR 775002 A4 User Manual
Page 62
3-28
ADS FlowShark Manual
Quantity
Description
ADS Part Number
as
required
ultrasonic depth sensor surcharge
mounting bracket
I40-0010
1
special predrilled 8-foot metal band
I40-0007
1
Extension cables can be ordered in specific lengths up to 300 feet. Note
the desired length (in feet) in the xxx portion of the part number. For
example, if the application requires a 50-foot extension cable for an
ultrasonic depth sensor, the part number would be 103228A–050.
2
Pressure depth sensors also are available in 0–15 PSI (p/n 3704–0042–
35) and 0–30 PSI (p/n 3704–0016–40).
Gathering the Tools and Equipment
Gather the following tools for the installation:
Battery-powered hammer drill with assorted bits, including the
following at a minimum:
3/8-inch x 4-inch (minimum length) masonry bit
¼-inch masonry bit (F35-0018)
5/16-inch carbide-tipped drill bit (include smaller bits)
4-pound hammer
Rubber mallet
24-inch carpenter’s level
Wrenches
Screwdrivers (flathead and Phillips head of assorted sizes)
3/8-inch x 16-inch threads tap
Diagonal wire cutters
Folding carpenter’s rule with a brass slide
Mastic tape (ADS p/n 507193) or rubber coaxial stretch tape