ADS Environmental Services FlowShark QR 775002 A4 User Manual
Page 161

Configuration and Activation 6-35
Press K compensates for drift in the pressure depth sensor and
generally reflects an average difference recorded over a designated
time period between pressure depth measurements and reliable
ultrasonic depth readings at the same monitoring point..
Diagnostics dialog for the Pressure 1 device following sensor firing
Click on the Advanced button to view more detailed
diagnostic information.
Verify the accuracy of the pressure depth and temperature
readings, and edit the configuration parameters as
necessary.
Note: Refer to Editing the Pressure Device on page 6-19
for descriptions of the individual configuration parameters.
Save these modifications to the LIF in the monitor as
follows:
Select the Store button to save any changes made in the
device parameters to the LIF in the database.