8-14
ADS FlowShark Manual
Entity Select the entity for which to output entity data
through the Analog Output.
Min Value Enter the data value that will correspond to
the weakest signal available in the scale (4 mA). This value
should reflect the lowest value possible for the data.
Max Value Enter the data value that will correspond to
the strongest signal available in the scale (20 mA). This
value should reflect the highest value possible for the data.
Manual Value Enter the value that will represent the
output when the Enable Manual option is selected. This
parameter applies only for testing purposes; therefore,
ADS does not recommend editing this value.
Enable Manual Select this checkbox to output the value
designated in the Manual Value field. ADS provides this
option only for testing purposes.
Note: Activate the monitor with the Enable Manual
option selected to perform the test based on the designated
Manual Value. Once the test is complete, disable this
option and reactivate the monitor to implement the Min
and Max Values entered for the output device.
Hold On Error Select this checkbox to maintain the last
output reading when the current value is in error.
5. Set up receiving instrument with ranges and units to match the
monitor outputs.
6. Mount the loop/monitor power supply outside the manhole, and
provide AC power.
7. Run the power and signal cables from the monitor to outside
the manhole, and then splice/seal to the end-run cables (i.e., the
loop power supply and signal terminations).
Note: Refer to the images on pages 8-15 and 8-16 and the
diagram on page 8-17 for additional details on typical loop
power and analog output connections.