ADS Environmental Services FlowShark QR 775002 A4 User Manual
Page 107
4-26
ADS FlowShark Manual
SMA-to-TNC adaptor (ADS p/n 507173) for antennas with
the SMA connector
Portable electric drill with assorted bit sizes (include ½-
inch and 3/8-inch bits)
8-inch cable ties
Post hole digger
Shovel
Sledge hammer
7/16-inch nut driver
Corbel drill with a ½-inch by 36-inch bit
Hacksaw
Commercial asphalt cold patch compound
Electrical duct seal
Rubber stretch tape
2. Mount the antenna to the pedestal:
Note: Some assembly may be complete upon delivery. If
this occurs, proceed to the next applicable step in the
installation process.
Drill a ½-inch hole in the center of the horizontal top
portion of the bracket attached to the base of the pedestal.
Drilling hole in top bracket