6-20
ADS FlowShark Manual
file containing the pressure coefficients to the local directory
from the ADS website in the following way:
Access the ADS websit
Internet.
Select Environmental Services > Support > Client
Services.
Click on the Download pressure coefficients… link.
Right-click on the year in which the sensor was
manufactured, and select the Save Target As option.
Rename the file to reflect the following format:
pressure.xx, where xx represents the last two digits of the
year in which the sensor was manufactured. Remove the
.txt extension!
Save the file to the appropriate location in the local file
system.
Pipe Height This field displays the pipe height at the monitor
location. This parameter is not editable from this location.
Physical Offset Enter the vertical distance from the bottom
of the pressure depth sensor to the bottom center of the pipe.
ADS recommends measuring this distance manually during the
monitor installation or confirmation process. Profile defaults to
0 inches.
Electronic Offset Enter the difference that exists between
the pressure depth sensor readings and the manually measured
depth. The default value is 0 inches.
Editing the MLI Device
Typically, the MLI device will not require editing. However, if the
monitor will be supporting activities such as water quality sampling,
event notification, or dual data rates, refer to the Profile User’s
Guide (#950015**) for detailed instructions on properly setting the
applicable parameters.