FlowShark Models and Capabilities B-3
Model 5000-BG
(Dual Pipe, Wireless Modem)
Modbus ASCII (requires external power)
Modem - wireless
Power, external – available as an option running 12 volts at 1.2A
Power, internal – two 12-volt alkaline batteries – one for powering
monitor one for powering wireless modem
Sensors – two each - pressure, ultrasonic & velocity
Model 5000-BL
(Dual Pipe, Land Line Modem)
Modbus ASCII (Supported if external power is available.)
Modem - land line
Power, external - available as an option running 12 volts at 1.2A
Power, internal - two 12-volt alkaline batteries operating in parallel
Sensors - two each - pressure, ultrasonic & velocity
Model 5000-CG
(Single Pipe, 4-20 mA, Wireless Modem)
4-20mA input/output - supports two each
Modbus ASCII
Modem - wireless
Power, external (required) - running 12 volts at 1.2A
Rain Gauge (using I/O connector)
Sensors - one each - pressure, ultrasonic & velocity
Water Quality Sampler (using I/O connector)