4 viewing and clearing events – Rockwell Automation DeviceNet Communications Module User Manual
Page 102
![background image](/manuals/581763/102/background.png)
9-6
DeviceNet Communications Module
9.4
Viewing and Clearing Events
The module maintains an event queue that reports the history of its
actions. You can view the event queue using VS Utilities (Version
3.01 or higher) software.
14
Drv 2 Feedback
Feedback from MDI drive 2 being received by the module.
15
Drv 3 Reference
Reference being transmitted from the module to MDI drive 3.
16
Drv 3 Logic Cmd
Command being transmitted from the module to MDI drive 3.
17
Drv 3 Logic Sts
Status of MDI drive 3 being received by the module.
18
Drv 3 Feedback
Feedback from MDI drive 3 being received by the module.
19
Drv 4 Reference
Reference being transmitted from the module to MDI drive 4.
20
Drv 4 Logic Cmd
Command being transmitted from the module to MDI drive 4.
21
Drv 4 Logic Sts
Status of MDI drive 4 being received by the module.
22
Drv 4 Feedback
Feedback from MDI drive 4 being received by the module.
23
DN Rx Errors
Current value of the DeviceNet CAN Receive Error Counter
register.
24
DN Tx Errors
Current value of the DeviceNet CAN Transmit Error Counter
register.
25
Data Rate SW
Current setting of the module 2-bit data rate switch.
26
Node Address SW
Current setting of the 6-bit Node address switch.
Table 9.5 – Diagnostic Items Accessed Using VS Utilities in Multi-Drive Mode
(Continued)
No.
Name
Description
Figure 9.2 – VS Utilities Event View/Clear Screen