Rockwell Automation 8720MC Drives Integration Manual User Manual
Page 197

Publication 8720MC-IN001D-EN-P — December 2002
8720SM Motor Specifications and Performance Curves
D-9
Figure D.6
8720SM-022S2GA Motor with 8720MC-B048 Drive
Figure D.7
8720SM-030S4JA Motor with 8720MC-B065 Drive
Figure D.8
8720SM-037S4KA Motor with 8720MC-B078 Drive
0
0
1000
2000
3000
4000
5000
6000
7000
8000
9000
RPM
kW
Maximum kW
S6 (50%ED) kW
Performance assumes regenerative
converter with 750V dc bus and
505V ac at motor.
Amps at Base Speed -
Cont Amps 13.5
S6 Amps 17.2
Max Amps 18.7
6
12
18
24
30
36
42
48
54
60
0
1000
2000
3000
4000
5000
6000
7000
8000
9000
RPM
Torque in N-m
S6-50%
Rated
Maximum
Torque in N-m
Rated 35
S6-50% 47.5
Max. 52.5
Continuous (S1) kW
9
8
7
6
5
4
3
2
1
0
0
5
10
15
20
25
30
35
40
45
50
0
1000
2000
3000
4000
5000
6000
7000
RPM
RPM
kW
Maximum kW
S6 (50%ED) kW
Continuous (S1) kW
Amps at Base Speed -
Cont Amps 63.1
S6 Amps 74.6
Max Amps 88.5
0
30
60
90
120
150
180
210
240
270
300
0
1000
2000
3000
4000
5000
6000
7000
Torque in N-m
Maximum
Torque in N-m
Rated 192
S6-50% 235
Max. 288
S6-50%
Rated
Performance assumes regenerative
converter with 750V dc bus and
505V ac at motor.
0
10
20
30
40
50
60
0
1000
2000
3000
4000
5000
6000
7000
RPM
RPM
kW
Maximum kW
S6 (50%ED) kW
Continuous (S1) kW
Amps at Base Speed -
Cont Amps 76.1
S6 Amps 89.2
Max Amps 107
0
36
72
108
144
180
216
252
288
324
360
0
1000
2000
3000
4000
5000
6000
7000
Torque in N-m
Maximum
Torque in N-m
Rated 238
S6-50% 285
Max. 355
S6-50%
Rated
Performance assumes regenerative
converter with 750V dc bus and
505V ac at motor.