beautypg.com

Rockwell Automation 8720MC Drives Integration Manual User Manual

Page 150

background image

Publication 8720MC-IN002A-EN-P — December 2002

C-38

Programming Parameters

Name: At_Spd_Window

Data Display: Integer

R/W

Parameter No.
157
File:
Status/Faults
Group:
Setup

Description: The velocity window relates the current velocity to the velocity command value (parameter 36). If
the current velocity feedback value falls within the calculated velocity window, the drive sets the status
n feedback = n command” (parameter 330). A value of zero disables the occurrence of the At_Prog_Speed
event, parameter 330

Default:
10

Length
2 bytes

SCANport Min/Max
Min.

≥ 0

Max.

≤ +30,000

SCANport Scaling Resolution
1 RPM, range - 0 to +30,000 RPM

Units
RPM

Default:
5

Length
4 bytes

SERCOS/DPI Min/Max
Min.

≥ 0

Max.

≤ +2

31

- 1

SERCOS/DPI Scaling Resolution
Scaling type: parameter 44
Scaling factor: parameter 45
Scaling exponent: parameter 46

Units
parameter
44

Name: Max_Foll_Error

Data Display: Integer

R/W

Parameter No.
159
File:
Status/Faults
Group:
Setup

Description: Monitoring window. By means of the monitoring window, the maximum position deviation, as
referenced to the active actual position value, can be defined for the position feedback value. When the position
error value exceeds the maximum position window value, the drive sets an error for excessive position deviation
in C1D (parameter 11).

Default:
30,000

Length
2 bytes

SCANport Min/Max
Min.

≥ 0

Max.

≤ +65535

SCANport Scaling Resolution
360/parameter 79, default: with parameter 79 at
3600 cnts/rev, increment = .1 degree, Range = 0 to
+3276.7 degrees

Units
Param 79
counts/rev

Default:

+2

31

- 1

Length
4 bytes

SERCOS/DPI Min/Max
Min.

≥0

Max.

≤ +2

31

- 1

SERCOS/DPI Scaling Resolution
Scaling type parameter 76
Scaling factor parameter 77
Scaling exponent parameter 78
Rotational position resolution parameter 79

Units
parameter
76