Configuring a LAN Logistics Server to DH485 (NetBios)
For information on the configuration characteristics for a LAN Logistics Server to
DH485 (NetBios), see Table 3.AF.
Table 3.AF
Configuration Characteristics for Configuring a LAN Logistics Server to
DH485 (NetBios)
If you want to:
Press this key:
Assign a unique communication device name (1-8 characters). This
field must be defined for the software to accept the configuration.
You cannot modify this field. The communication device name that
you assign appears at the top of the screen when you use WHO.
F1
Device Name
Assign a description for a communication device (1-50 characters).
You must define this field for the software to accept
the configuration.
F2
Enter Device Description
Select the LAN Logistics Server to DH485 (NetBios) option.
F3
Select Interface Hardware
Assign a timeout for processor reply. Available choices are: 15, 20,
25, 30, 35, 40, 45, 50, 55 and 60 seconds. The default is
20 seconds.
F4
Online Wait for Reply
Enter default Novell Netware Server name (1- 9 characters).
F5
Default Server Name
Enter a programming terminal name (1- 8 characters).
F6
Terminal Name
Enter the 1785-KA5 DH+ address (0-77 octal).
F8
1785-KA5 Address
Enter a destination link DH+ address (decimal).
F9
Destination Link