Configuring Communications
3-17
Configuring a WinLinx/RSLinx Driver (DH+)
For information on the configuration characteristics for a WinLinx/RSLinx Driver
(DH+), see Table 3.M.
Table 3.M
Configuration Characteristics for the WinLinx/RSLinx Driver (DH+)
If you want to:
Press this key:
Assign a unique communication device name (1-8 characters). This
field must be defined for the software to accept the configuration.
You cannot modify this field after you save the configuration. The
communication device name that you assign appears at the top of
the screen when you use WHO.
F1
Device Name
Assign a description for a communication device (1-50 characters).
You must define this field for the software to accept
the configuration.
F2
Enter Device Description
Select the WinLinx/RSLinx (DH+) option.
F3
Select Interface Hardware
Assign a timeout for processor reply. Available choices are: 15, 20,
25, 30, 35, 40, 45, 50, 55 and 60 seconds. The default is
20 seconds.
F4
Online Wait for Reply
Enter KT device driver name (1-8 characters). The default
is KTDRV1.
F5
Default Server Name
Enter a programming terminal name (1-8 characters).
F6
Terminal Name
Define the following:
·Network mode (choose between: local, remote, and DH+ routing)
·Local node address (octal)
·Remote address (octal)
·Destination link ID (decimal) for DH+ routing
·Bridge address (octal) for DH+ routing
The default network mode is local.
F9
Network Mode