Configuring the numeric data display – Rockwell Automation 2711E-ND1 PanelBuilder 1400E Reference Manual User Manual

Page 62

background image

55

Numerics

Publication 2711E-820 – January 1998

If Polarity is unassigned, and the
Decimal Display option is set to

This value is displayed

Disabled

3124

Implicit

3124

PLC Controlled at 1 digit

312.4

Fixed Position at 5 digits

.03124

The following table illustrates how the value of the Polarity
control determines the display. The Displayed Value control’s
value is –3124.

If the Decimal Display is set to Implicit,
and the Polarity control is this value

This value is displayed

Unassigned

–3124

0

3124

1

–3124

Configuring the Numeric Data Display

Configure the Numeric Data Display according to the following
table:

Field

Meaning

Name

Assign a name, up to 15 characters, to document the object for
printed reports. This increases the application’s size by 1 byte
per character.

Fill Left With

Choose whether the left portion of the display will be filled with
zeroes or blank spaces when fewer than the maximum number
of digits are displayed.

Number of Digits

Specify the number of digits to display, up to a maximum of 16.
Keep in mind that a decimal point and minus sign each take one
digit.

At runtime, if the value can’t be displayed within the number of
digits specified for the object, a string of asterisks (*) is
displayed.

Decimal Display

How you configure the decimal display and polarity determines
the appearance and behavior of the Numeric Data Display. (See
the examples before this table.) The configuration also
determines the tags or expressions you must assign. Each
Numeric Data Display can have only one configuration.

Disabled—Select this item if you don’t want any decimal point
displayed. If the Displayed Value control contains a decimal
point, it will be rounded off.