Rockwell Automation 1785-Lx0C15 ControlNet PLC-5 Programmable Controllers User Manual User Manual
Page 85
1785-UM022C-EN-P - February 2008
4-5
The fields of the CT data type that you can directly address are:
The CIP Generic and Generic Bi-directional CIO command types
allow you to enter any possible CIP command over the ControlNet
network. This allows the processor to send commands to devices not
listed in the command type list, or to send special CIP commands to
devices. Use of these command types requires specific details of the
device to which the command is being sent.
For more detailed information about writing ladder programs, see
your programming software documentation.
Sending Continuous Messages
If you use continuous mode message instructions, do not toggle the
rung condition unless the continuous message is done or errored.
Once enabled, the continuous message will only stop under the
following conditions:
•
if a message error is detected
•
if you reset the message CO bit
•
if you set the TO status bit
You can change the CO and TO bits through the message block
configuration screen or with ladder logic.
Field
Definition
Location
.EW
Enabled-waiting flag bit
word 0, bit 02
.CO
Continuous control bit
word 0, bit 03
.ER
Errored flag bit
word 0, bit 04
.DN
Done flag bit
word 0, bit 05
.ST
Started flag bit
word 0, bit 06
.EN
Enabled flag bit
word 0, bit 07
.TO
Abort (Time out) control bit
word 0, bit 08
.ERR
Error-code word
word 1
.RLEN
Requested length word
word 2
.DLEN
Done length word
word 3
.FILE
Transfer file number
word 4
.ELEM
Transfer element number
word 5
.DATA[0] through.DATA[15]
Remaining words
words 6 through 21