Error codes, Initialization – Rockwell Automation 57RF RFID ICODE Handheld Interface User Manual User Manual
Page 96

96
Rockwell Automation Publication 57RF-UM001A-EN-P - September 2011
Chapter 8
The RFID ICODE handheld interface acts slowly.
• The unit may be short of program memory or storage memory.
• Increase the amount of storage or program memory through the System
control in the Control Panel.
• You can also delete any unnecessary files.
I get little or no sound from the RFID ICODE handheld interface.
• Adjust the volume and sound properties via the Volume and Sound control
in the Control Panel.
The RFID ICODE handheld interface does not recognize a compact flash or
device card.
• The card is not installed or seated properly.
• Reinstall the card. There may be an unstable connection between the card
and the RFID ICODE handheld interface.
• Remove the card, clean the edge connector with a soft dry cloth, and
reinstall the card.
The RFID ICODE handheld interface goes into auto-suspend after a short
period of inactivity.
• As a default, the device will auto-suspend after two minutes of inactivity
while running on batteries and after thirty minutes of inactivity when
running on AC power.
• Adjust the power management properties via the Power control in the
Control Panel.
No sound is heard when you tap the touch screen or press a key.
• Volume setting is low or turned off.
• Check the volume slider in the Volume & Sound properties dialog box in
the Control Panel.
Error Codes
Initialization
The RFID ICODE handheld interface will return the following error codes if an
error occurs during initialization:
Value Description
100 Not
initialized
101
Could not open COM port
102
Could not turn on auxiliary power
103