beautypg.com

Navigation, Working with tags, Read/write times – Rockwell Automation 57RF RFID ICODE Handheld Interface User Manual User Manual

Page 75: Reading tags, Read/write times reading tags

background image

Rockwell Automation Publication 57RF-UM001A-EN-P - September 2011

75

Chapter 7

Navigation

There are multiple ways to navigate inside the RFID software. Tap on any text
field (such as Start, Length, or UID) using the stylus to edit it. Double-tap a text
field to highlight the text. Use the scroll bar to view the contents of the data grid.
Additionally, users can tap anywhere within the data grid and use the arrow keys
to move up, down, left, and right within the grid.

Figure 35 - Arrow Keys, 52-Key Keypad

Figure 36 - Arrow Key, 45-Key Keypad

Working with Tags

Read/Write Times

Refer to the following table for tag read/write times:

Reading Tags

Single Tag Read to Screen

Deselect the check box marked Continuous for single tag read. Specify the start
byte and the length of data you want to read. Enter a length of “0” to read the
entire tag. Select the data mode or radix (binary, decimal, hexadecimal, or ASCII)
using the drop-down menu. Position the tag and push the Read button.

Tag Type

User Memory

Read Time

Write Time

SLI 128

112 Bytes

0.254 s

0.59 s

SLI-S 256

160 Bytes

1.27 s

2.95 s

SLI-L 64

32 Bytes

0.47 s

0.95 s

FRAM 2K

2000 Bytes

6 s

11 s

IMPORTANT

Start and Length values must be in increments of 4 or 8 bytes, depending
on block size.