9 Term definition

Measuring circuit monitoring of the analog outputs

Underrange:
- Current output 4 to 20 mA

- Current output 0 to 20 mA

- Voltage output 0 to 10 V

Dropping to 3.8 mA,
then jump to the configured signaling
Dropping to -0.1 mA,
then jump to the configured signaling
Dropping to -0.1 V,
then jump to the configured signaling

Overrange:
- Current output 4 to 20 mA

- Current output 0 to 20 mA

- Voltage output 0 to 10 V

Rising to 20.5 mA,
then jump to the configured signaling
Rising to 20.5 mA,
then jump to the configured signaling
Rising to 10.25 V,
then jump to the configured signaling

Probe short circuit or
probe/cable break
and alarms:
- Current output 4 to 20 mA

- Current output 0 to 20 mA

- Voltage output 0 to 10 V

Positive signaling: > 21.6 mA
Negative signaling: < 3.6 mA
Positive signaling: > 21.6 mA
Negative signaling: < -0.1 mA
Positive signaling: > 10.5 V
Negative signaling: < -0.1 V

Output behavior

The output behavior (positive or negative signaling) can be con-
figured.