beautypg.com

Technical data – HYDAC CS 1000 User Manual

Page 94

background image

ContaminationSensor CS1000

Technical data

HYDAC Filtertechnik GmbH

en

Page 94 / 100

BeWa CS1000 3247149n en 2009-02-04.doc

2009-02-04

Technical data

General data

Mounting position

Any (recommended: vertical position)

Self-diagnosis

Continuously with error display
via status LED and display

Display (only CS 1x2x)

LED, 6 digits, in 17 segment format

Measurement categories

CS 12xx

ISO / SAE

CS 13xx

ISO / SAE / NAS

Service categories

Flow (ml/min)
Out

(mA) or (VDC), according to model

Drive (%)
Temp (°C) and (°F)

Ambient temperature range

-30° ... +80° C / -22° ... 176° F

Storage temperature range

-40° ... +80° C / -40° ... 176° F

Relative humidity

Max. 95%, non-condensing

Sealing material

CS 1xx0 = FPM
CS 1xx1 = EPDM

Protection class

III (low voltage protection)

Protection system

IP67

Weight

1.3 kg

Electrical data

Connection plug

M12x1, 8 pole, specified in DIN VDE 0627

Power supply voltage

9 – 36 V DC, residual ripple < 10% (reverse
polarity protection)

Power consumption

3 Watt max.

Analog output

2-conductor technology
4 - 20 mA active output (max. burden 330Ω)
or
0 - 10 V active output (min. load resistor
820Ω)

Switching output

Passive, n-switching Power MOSFET:
max. current 1.5 A, normally open

RS485 Interface

2 wire, half duplex

HSI (HYDAC Sensor Interface)

1 wire, half duplex