Nasmax – HYDAC CS 1000 User Manual
Page 70

ContaminationSensor CS1000
Analog Output (ANAOUT)
HYDAC Filtertechnik GmbH
en
Page 70 / 100
BeWa CS1000 3247149n en 2009-02-04.doc
2009-02-04
NAS 1638 - National Aerospace Standard (Only CS 13xx)
The following NAS values can be output via the analog output:
• NAS Maximum (
NAsMAX
)
Only one value is output.
• NAS (2 / 5 / 15 / 25)
All values are sequentially time-coded before output.
• NAS 2 / NAS 5 / NAS 15 / NAS 25
Only one value is output.
• NAS + T
All values are sequentially time-coded before output.
• HDA.NAS
All values are sequentially time-coded before output.
Primarily this signal was planned for the HDA 5500 (HYDAC digital display Unit),
however, this can use in other applications.
The current range I=4.8 - 19.2 mA or voltage range U=2.4 - 9.6 V DC depends on
the contamination class according to NAS=0.0 - 14.0 (resolution 0.1 class).
Current I
NAS class / error
Voltage U
I <4.00 mA
Cable break
U <2.00 V
4.0 mA < I < 4.1 mA
Device error, device not ready
2.00 V < U < 2.05 V
4.1 mA < I < 4.3 mA
Not defined
2.05 V < U < 2.15 V
4.3 mA < I < 4.5 mA
Flow error (flow insufficient)
2.15 V < U < 2.25 V
4.5 mA < I < 4.8 mA
Not defined
2.25 V < U < 2.40 V
I = 4.80 mA
NAS 0
U = 2.4 V
I = 4.90 mA
NAS 0.1
U = 2.45 V
I = 5.01 mA
NAS 0.2
U = 2.51 V
...
...
...
I = 5.83 mA
NAS 1
U = 2.92 V
I = 6.86 mA
NAS 2
U = 3.43 V
I = 7.89 mA
NAS 3
U = 3.95 V
I = 8.91 mA
NAS 4
U = 4.46 V
I = 9.94 mA
NAS 5
U = 4.97 V
I = 10.97 mA
NAS 6
U = 5.49 V
I = 12.00 mA
NAS 7
U = 6.00 V
I = 13.03 mA
NAS 8
U = 6.52 V
I = 14.06 mA
NAS 9
U = 7.03 V
I = 15.09 mA
NAS 10
U = 7.55 V
I = 16.11 mA
NAS 11
U = 8.06 V
I = 17.14 mA
NAS 12
U = 8.57 V
I = 18.17 mA
NAS 13
U = 9.09 V
...
...
...
I = 18.99 mA
NAS 13.8
U = 9.50 V
I = 19.10 mA
NAS 13.9
U = 9.55 V
I = 19.20 mA
NAS 14.0
U = 9.60 V