Selecting the measurement point

Proceed carefully when selecting a suitable measuring point in order to obtain
cleanliness values that are continuous and coherent in real time.

A

B

2

A

B

1

3

A

2

1

B

INCORRECT INCORRECT

OK

1

The test point has to be selected so that the measured volume is taken
from a turbulent flow area, e.g. a pipe bend.

2

The CS has to be installed in the vicinity of the test point in order to obtain
precision-timed results.

3

While installing the measurement line, avoid creating a "siphon" trap for
sedimentation (particle deposits in the line).