beautypg.com

Outsde, Single – HYDAC CS 1000 User Manual

Page 47

background image

ContaminationSensor CS1000

Using switching output

HYDAC Filtertechnik GmbH

en

Page 47 / 100

BeWa CS1000 3247149n en 2009-02-04.doc

2009-02-04

Within limits

Becomes conductive again, when
a value < respective lower limit
or
a value > respective upper limit

OUTSDE

Outside of limits

A value ≤ respective lower limit
or
a value ≥ respective upper limit

After switching on or starting a
test.
Becomes conductive again when
the respective lower limit < all
values < respective upper limit

OFF

No switching
function

-

Always CONDUCTIVE except in
the event of an error

Mode 3 (M3)

Switching output – OPEN

Switching output –

CONDUCTIVE

5 consecutive tests ≤ limit value or
measurement stopped

Test is currently in progress and
one or more of the last 5
measured values > limit

Mode 4 (M4)

Switching output – OPEN

Switching output –

CONDUCTIVE

Start or result of
check
measurement after
test cycle time: a
value ≥ upper limit

For max. 5 consecutive tests:
all values ≤ respective lower limit
or testt stopped

Test is in progress and during one
or more of the last 5
measurements: a value >
respective lower limit

When test cycle
time elapsed, for
the duration of a
check
measurement

Is open again when all values <
respective upper limit Restart test
cycle time

Test cycle time has elapsed

Single mode

SINGLE

Switching output – OPEN

Switching output –

CONDUCTIVE

-

Device ready function
Always CONDUCTIVE except in
the event of an error