beautypg.com

Cs1000 features, Cs1000 restrictions on use, Notice – HYDAC CS 1000 User Manual

Page 16

background image

ContaminationSensor CS1000

CS1000 Features

HYDAC Filtertechnik GmbH

en

Page 16 / 100

BeWa CS1000 3247149n en 2009-02-04.doc

2009-02-04

CS1000 Features

The CS1000 Series ContaminationSensor is a stationary measurement unit for the
continuous monitoring of solid particle contamination in hydraulic and lubrication
systems.

The CS is designed to be used in low- or high-pressure hydraulic and lubrication
circuits and test benches where a small amount of oil (between 30 ml/min and 300
ml/min) is diverted for measurement purposes.

The ContaminationSensor is approved for a maximum operating pressure (see
specification on type label) and viscosity of up to 1000 mm²/s.

The particulate contamination is recorded by an optical measurement cell.

The sensor is available with the following options:
• with or without 6-digit display and keypad (can be rotated by 270°)
• with a 4 - 20 mA or 0 - 10 V analog output
• results are output as a cleanliness code according to:

ISO 4406:1999 and SAE AS 4059(D) or
ISO 4406:1987 and SAE AS 4059(D) or NAS

• pipe / hose installation or flange installation
All models feature an analog output and an RS485 interface for outputting the
measured cleanliness class. They also have a switch output set to switch at either
increasing or decreasing cleanliness.

CS1000 Restrictions on use

NOTICE

Prohibited operating fluids

The CS will be destroyed.

► Operate the CS1000 only in conjunction with the permitted operating fluids.

► CS 1xx0 is suitable for operation with petroleum or petroleum-based

refinates.

► The CS 1xx1 is suitable for phosphate esters.

► Observe the maximum operating pressure on the CS 1000 type label.