Hda.sae – analog signal sae to the hda 5500, Contaminationsensor cs1000 analog output (anaout), Hydac filtertechnik gmbh – HYDAC CS 1000 User Manual
Page 53

ContaminationSensor CS1000
Analog Output (ANAOUT)
HYDAC Filtertechnik GmbH
en
Page 53 / 100
BeWa CS1000 3247149n en 2009-02-04.doc
2009-02-04
HDA.SAE – Analog signal SAE to the HDA 5500
The HDA.SAE signal consists of 6 values (START / SAE A / SAE B / SAE C / SAE
D / Status) which are output sequentially. Synchronization with the downstream
control unit is a prerequisite.
The signal output is as follows:
Time
Measurement
category
Signal duration
in s
Current/Voltage
Start signal 0
--
2
20 mA / 10 V
Pause
2
4 mA / 2 V
Signal 1
SAE A
2
Current/Voltage for signal
Pause
2
4 mA / 2 V
Signal 2
SAE B
2
Current/Voltage for signal
Pause
2
4 mA / 2 V
Signal 3
SAE C
2
Current/Voltage for signal
Pause
2
4 mA / 2 V
Signal 4
SAE D
2
Current/Voltage for signal
Pause
2
4 mA / 2 V
Signal 5
Status
2
Current/Voltage for signal
Pause
30
4 mA / 2 V