beautypg.com

Hda.sae – analog signal sae to the hda 5500, Contaminationsensor cs1000 analog output (anaout), Hydac filtertechnik gmbh – HYDAC CS 1000 User Manual

Page 53

background image

ContaminationSensor CS1000

Analog Output (ANAOUT)

HYDAC Filtertechnik GmbH

en

Page 53 / 100

BeWa CS1000 3247149n en 2009-02-04.doc

2009-02-04

HDA.SAE – Analog signal SAE to the HDA 5500

The HDA.SAE signal consists of 6 values (START / SAE A / SAE B / SAE C / SAE
D / Status) which are output sequentially. Synchronization with the downstream
control unit is a prerequisite.

The signal output is as follows:

Time

Measurement

category

Signal duration

in s

Current/Voltage

Start signal 0

--

2

20 mA / 10 V

Pause

2

4 mA / 2 V

Signal 1

SAE A

2

Current/Voltage for signal

Pause

2

4 mA / 2 V

Signal 2

SAE B

2

Current/Voltage for signal

Pause

2

4 mA / 2 V

Signal 3

SAE C

2

Current/Voltage for signal

Pause

2

4 mA / 2 V

Signal 4

SAE D

2

Current/Voltage for signal

Pause

2

4 mA / 2 V

Signal 5

Status

2

Current/Voltage for signal

Pause

30

4 mA / 2 V