Iso 4 / iso 6 / iso 14 (iso 4 / iso 6 / iso 14), Iso code (iso), 3-digit, Iso 4 / iso 6 / iso 14 – HYDAC CS 1000 User Manual
Page 58: Iso code, Digit

ContaminationSensor CS1000
Analog Output (ANAOUT)
HYDAC Filtertechnik GmbH
en
Page 58 / 100
BeWa CS1000 3247149n en 2009-02-04.doc
2009-02-04
ISO 4 / ISO 6 / ISO 14 (
ISO 4 / ISO 6 / ISO 14
)
The ISO x setting enables the value of a class to be continuously output via the
analog output.
ISO code (
ISO
), 3-digit
The ISO code signal consists of 3 measured values (>4µm
(c)
/ >6µm
(c)
/ >14µm
(c)
)
and is time-coded with the following time slices.
4,0
4,1
I (mA)
1
3
2
4
6
2
5
1
U (V)
t (ms)
4,8
19,2
High
High
Low
Low
300
3000
3000
3000
9,75
19,5
2,15
2,05
2,0
9,85
19,7
0,0
19,8
9,9
Ti
me
Size
Signal duration
per pulse
in ms
Current (I) / Voltage (U)
1
Identifier
> 4 µm(c)
300
High / Low
2 Measured
value
> 4 µm(c)
3000
Current/Voltage for measured value
3
Identifier
> 6 µm(c)
300
High / Low / High / Low
4 Measured
value
> 6 µm(c)
3000
Current/Voltage for measured value
5
Identifier
> 14 µm(c)
300
High / Low / High / Low / High / Low
6 Measured
value
> 14 µm(c)
3000
Current/Voltage for measured value