beautypg.com

Analog output (anaout) – HYDAC CS 1000 User Manual

Page 48

background image

ContaminationSensor CS1000

Analog Output (ANAOUT)

HYDAC Filtertechnik GmbH

en

Page 48 / 100

BeWa CS1000 3247149n en 2009-02-04.doc

2009-02-04

Analog Output (ANAOUT)

Depending on CS model, the analog output is available as a 4 – 20 mA or 0 – 10 V
signal.

The CS model code allows you to detect the analog output.

CS Model code

Analog output

CS 1 x x x - A – x – x – x – x /-xxx

4 - 20 mA

CS 1 x x x - B – x – x – x – x /-xxx

0 – 10 V

The electrical design of the analog output must have already been taken into
consideration in the order. It is no longer possible to internally change the analog
output over later.

The following signals can be selected in the measurement menu:
• SAE classes acc. to AS 4059
• ISO Code acc. to 4406:1999
• ISO Code acc. to 4406:1987
• NAS class 1638
• Fluid temperature