ContaminationSensor CS1000

CS1000 in RS-485 bus

HYDAC Filtertechnik GmbH

en

Page 85 / 100

BeWa CS1000 3247149n en 2009-02-04.doc

2009-02-04

CS1000 in RS-485 bus

The CS1000 possesses an RS-485 interface which is to be used as a two-wire
interface in half-duplex operation.

The number of CS1000 per RS-485 bus is limited to 26 units because the HECOM
bus is addressed with the letters A – Z.

The length of the bus line and the size of the terminating resistance depend on the
quality of cable used.

The graphic below shows several CS1000 linked via the RS-485 interface and then
connected to a PC.

RS-485 +

RS-485 +

RS-485 +

max. 5 m

10

00 m

Data+ Data-

10 VDC …

30 VDC

RS-485 -

HECOM Bus address

HECOM Bus address

HECOM Bus address

HECOM Bus address

RS-485 -

RS-485 -

B

C

.
.
.

.
.

.
.

.
.

.
.

Z

A

1

3

4

2.1

2.2

US

B-

B

USB-A

PC

Item

Description

HYDAC

Part no:

1

Converter

RS232 <-> RS485

6013281

1

Converter

USB <-> RS485

6042337

2.1

Connector cable

RS232, 9-pole

-

2.2

Connector cable

USB [A] <-> USB [B]

-

3

Recommended cable

Twisted pair

-

4

Terminating resistance

≈ 120 Ω

-