Replacing the Transfer Unit

61

2

Grip the tabs at both ends of the
transfer cartridge

and gently lift it

out of the printer.

Attention

Lift the roller carefully to prevent
toner from spilling out.

3

Unpack a new transfer cartridge and
insert the knobs on both ends of the
cartridge into the U-shaped guides
inside the printer.

4

Lock the transfer cartridge into the
printer by pushing down on the base of
the tabs until you hear a click.

5

If you opened the imaging unit cover,
close it .

6

Close the front cover .

7

Turn on the printer .

8

In the Operator Control/Consumables/
Item Replaced/Transfer Unit menu
choose Yes to reset the consumables
usage monitoring system.

You must manually reset the consumables usage monitoring
system to ensure accurate consumables monitoring.