Requirements

154

If using a humidifier or water vaporizer in the room with the printer, use
only purified or distilled water. Impurities in the water may be released into
the air, where they can accumulate inside the printer and cause degraded
printer output.

Attention

Do not connect the groundwire to gas or water pipes or grounding for
telephones.

Power Requirements

WARNING!

Connect the power plug to an outlet with the same rated voltage as the
printer (120 or 240 V), and fused for at least 15 amperes (4 amperes for
240 V). No other devices should be connected to this outlet, as
overheating could cause fire or electric shock. The printer draws 8 A at
120 V, or 4 A at 240 V. Your printer requires a properly grounded AC
outlet with a rated line voltage of 120 V or 220–240 V. The grounding
terminal on the power cable should be connected to a good earth
ground to prevent electric shock and fire.

In compliance with UL guidelines, “The appliance inlet is considered to
be the main disconnect device.”

Power

North America

120 VAC 50 Hz 8 amps

Europe

220–240 VAC 50/60 Hz 4 amps

Latin America

115/120 VAC 50/60 Hz 8 amps
220–240 VAC 50/60 Hz 4 amps

Notes: Amperage capacity at least 1.2 times that used by
the printer.

Voltage
Fluctuation
Rate and Rated
Line Voltage

North America

120 VAC ±10%

Europe

220–240 VAC ±10%

Latin America

120 VAC ±10%
220–240 VAC ±10%

Notes: 10% of the rated line voltage for proper operation.

Frequency
Variation Rate

Within 50–60 ±3 Hz

Fused

For at least 15 amperes (8 amperes for 240 V).