Cuda 12000 IP Access Switch CLI-based Administration Guide
Configuring SNMP Access Control
173
Perform the following tasks to configure an SNMPv1 or v2c community.
Refer to the configuration example below:
Storage
Indicates how the SNMP community’s attributes
are stored. The options are:
■
volatile: The entry is stored in volatile
memory. The information is lost during a
system reboot.
■
nonvolatile (default): The entry is stored in
non-volatile memory. The information is not
lost during a system reboot.
■
permanent: The entry is stored in non-volatile
memory. You cannot delete the information
but you can make modifications.
■
readonly: The entry is stored in non-volatile
memory. You cannot delete or modify the
information.
Task
Command
1. Enter configuration mode.
root
2. Create an SNMP community
and a corresponding security
group.
snmp-server community
3. Specify the host that has access
to the SNMP community.
snmp-server community
4. Specify the Mask address for a
range of hosts.
snmp-server community
5. Name the SNMP context to be
used with the SNMP
community.
snmp-server community
[context
6. Display a specific SNMP
community or all SNMP
communities.
show snmp community [
7. Remove an SNMP community
and its security group.
no snmp-server community
Parameter