ADC CUDA 3 User Manual
Page 156

ADC Telecommunications, Inc.
154
C
HAPTER
8: T
IMING
AND
A
LARM
C
ONTROLLER
M
ANAGEMENT
To configure the faults for which you want to be notified, perform the
following tasks. By default, the fault reporting status is “disabled” for each
fault:
ps-ac
The power supply associated with the chassis
detected the loss of one or more AC inputs.
ps-dc
The power supply associated with the chassis
detected a DC out-of-range fault.
ps-temp
The power supply associated with the chassis
detected an over-temperature condition.
red-alarm
One or more payload blades has asserted a
Red Alarm.
yellow alarm
One or more payload blades has asserted a
Yellow Alarm.
Task
Command
1. Enter root mode.
root
2. Specify the faults that you
want reported.
chassis-fault {backplane |
backplane-power |
backplane-power-a |
backplane-power-b |
backplane-temp |
bits-a |
bits-b |
blue |
fan-rotation |
fan-temp |
local-pwr-a |
local-pwr-b |
processor-temp |
ps-ac |
ps-dc |
ps-temp |
red-alarm |
yellow}
Fault
Description