ADC CUDA 3 User Manual
Page 136

ADC Telecommunications, Inc.
134
C
HAPTER
7: P
ACKET
O
VER
SONET A
DMINISTRATION
B2 Signal Fail (SF)
Enabled by default, configures the
interface to report a failure when the
B2 signal degrades enough to meet or
cross a specified Bit Error Rate (BER)
threshold.
The default BER threshold for B2 signal
failure is 10-3.
■
To enable reporting:
pos report sf-ber
■
To disable reporting:
no pos report sf-ber
■
To set the B2 Signal Fail threshold:
pos threshold sf-ber
Loss of Frame (SLOF)
Enabled by default, configures the
interface to report section loss of frame
errors. The interface detects SLOF
when a severely error framing defect
on the incoming SONET signal persists
for at least 3 milliseconds.
■
To enable reporting:
pos report slof
■
To disable reporting:
no pos report slof
Loss of Signal (SLOS)
Enabled by default, configures the
interface to report loss of signal (SLOS)
errors. The POS interface reports a
SLOS error under either of the
following conditions:
■
When an all-zeros pattern on the
incoming SONET signal lasts at least
19(+-3) microseconds.
■
If the signal level drops below the a
specified threshold.
■
To enable reporting:
pos report slos
■
To disable reporting:
no pos report slos
Alarm Report
Description
Command