HP XP P9500 Storage User Manual
Page 532
5.
To add another physical path, repeat steps 2 through 4.
6.
If there are no more physical paths to be added, press the F3=Exit key in the Edit Port Definition
panel.
The Edit Logical Path Definition panel displays.
7.
If defining a path from the secondary site to the primary site, specify e in the AC column on
the Reverse line.
If no path will be defined from the secondary site to the primary site, proceed to step 11.
Edit Logical Path Definition
Command ===>
2008/02/28 16:07:39
Path Set ID . . . : TESTPATH
Description . . . : TEST
Attributes
Type . . . . . . . . DKC (DKC/CU)
SHR . . . . . . . . Y (Y/N)
Supported action: s(Select Storage System)
AC S/N Model IFType PathID CU SSID CCA
Primary 14002
USP
1515
00
Secondary 14001
USP
1515
00
Supported action: e(Edit physical path)
AC Assigned Physical Path
Forward 06->07
E Reverse
F1=Help F3=Exit F7=Backward F8=Forward F12=Cancel
8.
Press the Enter key.
The Edit Port Definition panel appears.
Edit Port Definition
Command ===>
Scroll ===> PAGE
2008/02/28 16:07:48
Supported action: d(Delete)
Path Set ID . . . : TESTPATH
Description . . . : TEST
S/N Model IFType PathID CU SSID
Primary . : 14002 USP 1515 00
Secondary : 14001 USP 1515 00
-------- Port ---------
AC Primary Dir Secondary
******************************* Bottom of data ********************************
F1=Help F3=Exit F5=Add F7=Backward F8=Forward F12=Cancel
9.
Press the F5=Add key.
The Assign Port panel displays.
10. Specify 07 for Primary Port Number and 06 for Secondary Port Number.
Edit Port Definition
Command ===> ADD Scroll ===> PAGE
.----------------------------------------------. 8/02/28 16:06:29
Supported a | Assign Port |
532 Using the ISPF panels