HP XP P9500 Storage User Manual
Page 331
Table 100 Using a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration (continued)
See:
Description
Target
Maintenance
or
failure
No.
Create a Continuous Access Journal Z copy pair between the primary site and
the remote site, and then change the configuration to a 2DC configuration
(Primary
→ Remote).
Intermediate site
storage system
maintenance
2
site storage
system
maintenance”
(page 335)
Suspend the Continuous Access Journal Z copy pair between the intermediate
site and the remote site, and then change the configuration to a 2DC
configuration (Primary
→ Intermediate).
Remote site storage
system maintenance
3
storage
system
maintenance”
(page 338)
Reverse the copy direction of the Continuous Access Journal Z copy pair between
the primary site and the intermediate site, and then change the configuration
Primary site host
maintenance
4
to a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration in which operation
is performed from the intermediate site (Intermediate
→ Primary, and Intermediate
→ Remote).
--
Operation in a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration is not
affected.
Intermediate site host
maintenance
5
--
Operation in a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration is not
affected.
Remote site host
maintenance
6
Suspend the Continuous Access Journal Z copy pair between the primary site
and the intermediate site, and then change the configuration to a 2DC
configuration (Intermediate
→ Remote).
Primary site storage
system failure
(volatile)
Failure
7
during a
primary
site storage
system
failure
(volatile)”
(page 342)
Suspend the Continuous Access Journal Z copy pair between the primary site
and the intermediate site, and then change the configuration to a 2DC
configuration (Intermediate
→ Remote).
Primary site storage
system failure
(nonvolatile)
8
during a
primary
site storage
system
failure
(nonvolatile)”
(page 342)
Create a Continuous Access Journal Z copy pair between the primary site and
the remote site, and then change the configuration to a 2DC configuration
Intermediate site
storage system
failure (volatile)
9
(Primary
→ Remote). During recovery, the Continuous Access Journal Z copy
pairs must be re-created between the primary site and the intermediate site,
and between the intermediate site and the remote site.
site storage
system
failure
(volatile)”
(page 343)
Create a Continuous Access Journal Z copy pair between the primary site and
the remote site, and then change the configuration to a 2DC configuration
Intermediate site
storage system
failure (nonvolatile)
10
(Primary
→ Remote). During recovery, the Continuous Access Journal Z copy
pair between the intermediate site and the remote site must be re-created.
Using a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration
331