Table 100 Using a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration (continued)

See:

Description

Target

Maintenance
or
failure

No.

maintenance”
(page 333)

“Performing
intermediate

Create a Continuous Access Journal Z copy pair between the primary site and
the remote site, and then change the configuration to a 2DC configuration
(Primary

→ Remote).

Intermediate site
storage system
maintenance

2

site storage
system
maintenance”
(page 335)

“Performing
remote site

Suspend the Continuous Access Journal Z copy pair between the intermediate
site and the remote site, and then change the configuration to a 2DC
configuration (Primary

→ Intermediate).

Remote site storage
system maintenance

3

storage
system
maintenance”
(page 338)

“Performing
primary

Reverse the copy direction of the Continuous Access Journal Z copy pair between
the primary site and the intermediate site, and then change the configuration

Primary site host
maintenance

4

site host

to a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration in which operation

maintenance”
(page 339)

is performed from the intermediate site (Intermediate

→ Primary, and Intermediate

→ Remote).

--

Operation in a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration is not
affected.

Intermediate site host
maintenance

5

--

Operation in a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration is not
affected.

Remote site host
maintenance

6

“Operating
procedure

Suspend the Continuous Access Journal Z copy pair between the primary site
and the intermediate site, and then change the configuration to a 2DC
configuration (Intermediate

→ Remote).

Primary site storage
system failure
(volatile)

Failure

7

during a
primary
site storage
system
failure
(volatile)”
(page 342)

“Operating
procedure

Suspend the Continuous Access Journal Z copy pair between the primary site
and the intermediate site, and then change the configuration to a 2DC
configuration (Intermediate

→ Remote).

Primary site storage
system failure
(nonvolatile)

8

during a
primary
site storage
system
failure
(nonvolatile)”
(page 342)

“Operating
procedure

Create a Continuous Access Journal Z copy pair between the primary site and
the remote site, and then change the configuration to a 2DC configuration

Intermediate site
storage system
failure (volatile)

9

during an

(Primary

→ Remote). During recovery, the Continuous Access Journal Z copy

intermediate

pairs must be re-created between the primary site and the intermediate site,
and between the intermediate site and the remote site.

site storage
system
failure
(volatile)”
(page 343)

“Operating
procedure

Create a Continuous Access Journal Z copy pair between the primary site and
the remote site, and then change the configuration to a 2DC configuration

Intermediate site
storage system
failure (nonvolatile)

10

during an

(Primary

→ Remote). During recovery, the Continuous Access Journal Z copy

pair between the intermediate site and the remote site must be re-created.

intermediate
site storage

Using a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration