Performing primary site storage system maintenance, Performing primary site storage system – HP XP P9500 Storage User Manual
Page 389

Table 102 Using a Delta Resync Configuration (continued)
See
Description
Target
Maintenance or
Failure
No.
“Primary Site Host
Failure” (page 421)
Perform a delta
resync, and then
Primary site host
failure
13
change the
configuration to a
Delta Resync
configuration in which
the operation is
performed from the
local site (Local
→
Primary, Local
→
Remote).
“Operating Procedure
During a Path Failure
Suspend Cnt Ac-S Z
copy pairs, and then
Path failure between
the Primary
→ Local
storage systems
14
change the
configuration to a
2DC configuration
(Primary
→ Remote).
NOTE:
A volatile storage system failure is one in which the storage system memory enters a
volatile state because of the failure, wherein copy pair information, as well as data, is completely
lost, and the hardware information must be configured.
This section explains the maintenance and troubleshooting procedures for a Delta Resync
configuration.
The figures in the procedures in this section use the following legend:
The itemized lists under the figures in the procedures describe the commands that must be executed
in the procedures.
Performing Primary Site Storage System Maintenance
This subsection explains the procedures for performing primary site storage system maintenance.
The procedure in this section uses the following legend:
Failover for Primary Site Storage System Maintenance
To perform failover:
1.
Stop operation at the primary site.
2.
From the local site, execute the YKSUSPND FLUSH command for the Continuous Access
Journal Z copy pair between the primary site and the remote site.
Using a Delta Resync Configuration 389