Table 101 Using a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration (continued)
See:
Description
Target
Maintenance
or failure
No.
failure
(nonvolatile) at
remote site 1
or 2”
(page 378)
Delete either Continuous Access Journal Z
copy pair, and then reverse the copy
Primary site host failure (When operations
can be performed on both Continuous
Access Journal Z copy pairs)
11
direction of the remaining Continuous Access
Journal Z copy pair. Create a Continuous
Access Journal Z copy pair between both
remote sites, and then change the
configuration to a 3DC Multi-Target (Cnt Ac-J
Z x Cnt Ac-J Z) configuration in which
operation is performed from the
failover-destination remote site.
Perform a Reverse Resync operation for the
Continuous Access Journal Z copy pair on
which operations can be performed.
Primary site host failure (When operations
can be performed on only one of the
Continuous Access Journal Z copy pairs)
12
(when
operations can
be performed
on only one of
the Continuous
Access Journal
Z copy pairs)”
(page 384)
After error recovery, resynchronize the
Continuous Access Journal Z copy pairs
Path failure between the storage systems
at the primary site and remote site 1, or at
the primary site and remote site 2
13
between the sites at which the path failure
occurred.
TIP:
A volatile storage system failure is a condition in which storage system memory enters a
volatile state due to a failure. The copy pair information and the data are completely lost, so the
hardware information must be reconfigured.
This section provides maintenance and troubleshooting procedures for 3DC Multi-Target (Cnt Ac-J
Z x Cnt Ac-J Z) configurations.
The figures in the procedures in this section use the following legend.
The bullet lists under the figures in the procedures show the commands that must be executed.
Performing primary site storage system maintenance
The following are the procedures for primary site storage system maintenance.
The procedure below applies when you perform a failover to remote site 1. To perform a failover
to remote site 2, replace remote site 1 with remote site 2 in the procedure.
Using a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration 355