beautypg.com

HP XP P9500 Storage User Manual

Page 523

background image

Figure 121 Volume configuration example of a device with a Non Gen'ed volume

If a local scan has been executed, steps 7 to 9 in the following procedure are not required.

To execute a device scan involving Non Gen'ed volumes on the primary site:

1.

Display the Main Menu panel and choose 1 Set Defaults.

The Set Defaults panel to specify various default values is displayed.

2.

Specify CONFIG01 in Configuration File Prefix and DADP in Local Device Address Domain ID.

Set Defaults
Command ===>

2008/02/26 15:28:18
Specify Default Settings

More: +
Configuration File Prefix . . . . CONFIG01
Local Device Address Domain ID . . DADP
ISPF Log Max . . . . . . . . . . . 0
Remote DKC Function . . . . . . . N
Preset RouteListID . . . . . . . .
Preset Route Label . . . . . . . .

Defaults and Options for Background Jobs
SEND Options . . . . . . USER(*)
Timeout Hours . . . . . 0
Timeout Minutes . . . . 30
Job Name Prefix . . . . YUKON37
JCL JOB Statement:

//JOBNAME JOB MSGCLASS=H,NOTIFY=YUKON37
//*

F1=Help F3=Exit F7=Backward F8=Forward F12=Cancel

3.

Press the F3=Exit key.

You are returned to the Main Menu panel.

4.

Choose 3 Discover/Define Configuration.

The Discover/Define Configuration panel is displayed.

5.

Choose 1 Discover HP Storage.

The Discover HP Storage Arrays panel is displayed. In the initial status, a list of storage systems
is not displayed because devices have not yet been scanned.

6.

Press the F4=Discover key.

The Scan Device Address Extent panel is displayed.

Acquiring volume information 523