Recovering, Preparing, Preparing recovering – HP XP P9500 Storage User Manual
Page 353: Operating procedure, During a, Path failure
However, step 1 is different. From the intermediate site, execute the YKDELETE command for the
Continuous Access Journal Z copy pair between the intermediate site and the remote site.
Recovering
For details about the recovering procedure required when a path failure occurs between the storage
systems at the primary site and the intermediate site, see the recovery procedure used when a
nonvolatile failure occurs in the intermediate site storage system. For details, see
in
“Operating procedure during an intermediate site storage system failure (nonvolatile)”
.
However, there is no need to perform step 2.
Operating procedure during a path failure between the storage systems at the
intermediate site and the remote site
The following are the operating procedures that must be performed when a path failure occurs
between the storage systems at the intermediate site and the remote site.
Preparing
If a path failure occurs between the storage systems at the intermediate site and the remote site,
perform the same preparatory procedure that is used when a nonvolatile failure occurs in the
remote site storage system. See
in
“Operating procedure during a remote
site storage system failure (nonvolatile)” (page 349)
.
Recovering
If a path failure occurs between the storage systems at the intermediate site and the remote site,
perform the same recovery procedure that is used when a nonvolatile failure occurs in the remote
site storage system. See
in
“Operating procedure during a remote site
storage system failure (nonvolatile)” (page 349)
Using a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration
The following table explains how to perform maintenance for a 3DC Multi-Target (Cnt Ac-J Z x Cnt
Ac-J Z) configuration and how to take action if a failure occurs.
For maintenance or troubleshooting for the primary site storage system, either of the two remote
sites can be selected as the failover destination. If a primary site storage system failure occurred,
you can view the consistency time of each Continuous Access Journal Z copy pair to select the site
that has the latest data update time as the failover destination.
Table 101 Using a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration
See:
Description
Target
Maintenance
or failure
No.
Create a Continuous Access Journal Z copy
pair between remote sites 1 and 2, and then
Primary site storage system maintenance
Maintenance
1
change the configuration to a 2DC
configuration (Remote 1
→ Remote 2, or
Remote 2
→ Remote 1).
Suspend the Continuous Access Journal Z
copy pair between the primary site and the
Storage system maintenance for remote site
1 or remote site 2
2
maintenance-target remote site, and then
change the configuration to a 2DC
configuration consisting of the primary site
and the other remote site.
Delete the Continuous Access Journal Z copy
pair between the primary site and the remote
Primary site host maintenance
3
site that is not the failover destination, and
Using a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration 353