HP XP P9500 Storage User Manual
Page 472
Table 107 Using a 4x4x4 Cascade Configuration
See
Description
Target
Maintenance or
Failure
Number
“Performing Primary
Site Storage System
Suspend Continuous
Access Synchronous Z
Primary site storage
system maintenance
Maintenance
1
copy pairs, and then
change the
configuration to a 4x4
configuration
(Intermediate
→
Remote).
Suspend Continuous
Access Synchronous Z
Intermediate site
storage system
maintenance
2
copy pairs, and then
resynchronize them
after maintenance has
finished.
“Performing Remote
Site Storage System
Suspend Continuous
Access Journal Z copy
Remote site storage
system maintenance
3
pairs, and then
resynchronize them
after maintenance has
finished.
Perform a reverse
resync on Continuous
Primary site host
maintenance
4
Access Synchronous Z
copy pairs, and then
change the
configuration to a
4x4x4 Multi- Target
configuration in which
operation is performed
from the intermediate
site.
—
Operation in the
4x4x4 Cascade
Intermediate site host
maintenance
5
configuration is not
affected.
—
Operation in the
4x4x4 Cascade
Remote site host
maintenance
6
configuration is not
affected.
“Operating Procedure
During a Primary Site
Suspend Continuous
Access Synchronous Z
Primary site storage
system failure (volatile)
Failure
7
Storage System Failure
(Volatile)” (page 489)
copy pairs, and then
change the
configuration to a 4x4
configuration
(Intermediate
→
Remote). The
Continuous Access
Synchronous Z copy
pairs whose S-VOLs
are in the storage
system in which the
failure occurred must
be deleted and then
recreated.
472 Maintenance and troubleshooting operations