Table 107 Using a 4x4x4 Cascade Configuration

See

Description

Target

Maintenance or
Failure

Number

“Performing Primary
Site Storage System

Suspend Continuous
Access Synchronous Z

Primary site storage
system maintenance

Maintenance

1

Maintenance”
(page 474)

copy pairs, and then
change the
configuration to a 4x4
configuration
(Intermediate

Remote).

“Performing
Intermediate Site

Suspend Continuous
Access Synchronous Z

Intermediate site
storage system
maintenance

2

Storage System

copy pairs, and then

Maintenance”
(page 478)

resynchronize them
after maintenance has
finished.

“Performing Remote
Site Storage System

Suspend Continuous
Access Journal Z copy

Remote site storage
system maintenance

3

Maintenance”
(page 482)

pairs, and then
resynchronize them
after maintenance has
finished.

“Performing Primary
Site Host

Perform a reverse
resync on Continuous

Primary site host
maintenance

4

Maintenance”
(page 484)

Access Synchronous Z
copy pairs, and then
change the
configuration to a
4x4x4 Multi- Target
configuration in which
operation is performed
from the intermediate
site.

Operation in the
4x4x4 Cascade

Intermediate site host
maintenance

5

configuration is not
affected.

Operation in the
4x4x4 Cascade

Remote site host
maintenance

6

configuration is not
affected.

“Operating Procedure
During a Primary Site

Suspend Continuous
Access Synchronous Z

Primary site storage
system failure (volatile)

Failure

7

Storage System Failure
(Volatile)” (page 489)

copy pairs, and then
change the
configuration to a 4x4
configuration
(Intermediate

Remote). The
Continuous Access
Synchronous Z copy
pairs whose S-VOLs
are in the storage
system in which the
failure occurred must
be deleted and then
recreated.

472 Maintenance and troubleshooting operations